Mechanical Mounting#
Dimensions#
tbd
Movement Mounting#
The dial must be sufficiently stable. The fixing hole must have a diameter of 12,3 mm. The movement must be fixed in vertical position. See the picture to the right for the position of mounting parts. The disc nut (7*) M12 x 1 has to be tightened with a special wrench tool (Art. No. 36761 @todo new number) and a torque wrench with a torque of 4.5 Nm +/- 0.2 Nm.
@todo add image
Caution: Using the movement 192t, the ring nut (5) and distance ring (6) must not be removed.
Caution: With the movement with short shaft (192) the rubber washer (3) must in no case touch the clock case. In case of damage of the clock case the movement can be blocked.